Home / Products / Metalbit / Metalbit Metallico / Metalbit Metallico 40
Metalbit Metallico 40
Description
Description

Multi-layer profiled sheets with Coperall Profile 40 that combine metal sheeting and a bituminous membrane with an embossed metal foil facing for an added aesthetic value.

Metalbit Metallico 40 sheets offer excellent noise-abatement and anti-drum values.

Layout
1. Profile 40 metal sheet
2. Polymer-bitumen compound for anti-drum and soundproofing
3. Nonwoven polyester mat
4. Polymer-bitumen compound for anti-drum and soundproofing
5. Embossed aluminium foil
Minimum gradient

7% nominal gradient subject to local building regulations

Sections and details
Technical features
Parameters Dimensions Tolerances
Total width 1042 mm – 5 mm
+ 10 mm
Cover width 1000 mm – 5 mm
+ 10 mm
Length from 200 to 14000 mm L ≤ 3000 mm ± 5 mm
L > 3000 mm ± 10 mm
Profile height 40 mm ± 2 mm
Span 250 mm ± 5 mm
Deviation of perpendicularity - 0,60%
Performance
Test Value Norms
Noise abatement value Rw = 28 dB UNI EN ISO 10140-2
UNI EN ISO 717-1
Sound generated by rainfall Lɪᴀ = 53,7 dB (A) UNI EN ISO 10140-1
UNI EN ISO 10140-5
Reaction to Fire B-s2, d0 UNI EN 13501-1
Resistance to external fire Bʀᴏᴏғ(t3) UNI EN 13501-5
Other properties
Material Dimensions, weight MOI and FS Uniformly distributed imposed load kg/m2, including own weight*
Thickness (mm) Weight (kg/m²) Jxx (cm⁴/m) Wxx (cm³/m) Span (m)
1,00 1,25 1,50 1,75 2,00 2,25 2,50
Aluminum 0,6 3,77 12,47 3,55 371 237 165 121 90 63 46
Aluminum 0,7 4,10 14,23 4,42 433 277 192 141 105 74 54
Aluminum 0,8 4,43 16,12 5,15 495 317 220 162 120 84 61
Aluminum 1,0 5,09 19,64 6,63 618 396 275 202 150 105 77
Coated steel
Aluzinc
Stainless steel
0,5 6,46 10,00 3,14 510 326 228 166 127 100 82
Coated steel
Aluzinc
Stainless steel
0,6 7,39 12,07 3,78 715 461 312 235 179 141 108
Coated steel
Aluzinc
Stainless steel
0,7 8,33 13,84 4,34 946 612 427 313 239 181 130
Coated steel
Aluzinc
Stainless steel
0,8 9,26 15,74 4,94 1104 704 487 356 271 213 154

N.B. Listed values are indicative and as tested in our laboratory. Static calculations are the responsibility of the Designer / Main Contractor.

* Calculated with a deflection value ≤ 1/200 L